Pump skid — 3D frame analysis

The complete frame (side rails + cross members + connected posts) solved live with proprietary beam elements — as Simcenter or Ansys would for a slender structure.
Skid 2400 × 1200 × 600 mm, S355 steel, 10 kN load at the centre of the roof: mid-span deflection = 11.19 mm over 16 beam elements (11 nodes).

Télécharger le diagnostic reproductible (.txt) Version JSON (.json)

The frame in 3D

unloaded frame deflected shape magnified ×13 pump unit (10 kN)

Hand check (11§)

BoundsDeflection (mm)
Lower bound — central cross member alone, rigid supports: F·l³/(48·E·I)2.38
Proprietary solver — complete frame11.19
Upper bound — side rails + cross member simply supported11.90

Frame composition

MemberCount
Posts (vertical, fixed base)4
Lower side rails (along x)2
Upper side rails (along x, split at mid-span)4
End cross members (along y, bottom + top)4
Central roof cross member (carries the pump unit)2

Method

Each member is an Euler-Bernoulli beam element (axial + torsion + bending in 2 planes), assembled with a change of reference frame. The deflection of a single beam is verified EXACT (δ = F·l³/(3·E·I), δ = F·l³/(48·E·I) simply supported) — the frame is the assembly of these elements.

Decision-support analysis — NOT a certification (2.711, §§): human validation and systematic procedures required.