Validation file — proprietary solvers

The 11§ proof: each solver is compared with an analytical or published reference, and its convergence under refinement is shown. A deviation that tends to zero is the validation; certifying a real part remains an engineer's review.
11§ method: independent analytical reference → computed result → deviation → convergence under mesh refinement. A solver is validated when the deviation decreases towards zero as the mesh is refined.

3D FEM — uniaxial tension

Reference: σ = F/A = 100 MPa (exact) · elongation u_x = σ·L/E = 0,04762 mm (converges ~1/n, linear T4 elements)
Meshσ_xx (MPa)σ deviationu_x max (mm)u deviation
1×1×1100.0000.000 %0.0566919.04 %
2×2×2100.0000.000 %0.0546814.83 %
4×4×4100.0000.000 %0.052229.66 %
8×8×8100.0000.000 %0.050185.37 %

Thermo-mechanical — restrained expansion

Reference: σ_xx = −E·α·ΔT = −151,2 MPa (exact, any ν)
Meshσ_xx (MPa)referencedeviation
2×2×2-151.200-151.2000.000 %
4×4×4-151.200-151.2000.000 %
6×6×6-151.200-151.2000.000 %

3D CFD — Poiseuille (square duct)

Reference: exact Fourier series u_centre = 0,073672
Resolutionu_maxreferencedeviation
8×80.0714430.0736723.025 %
16×160.0730410.0736720.857 %
32×320.0735030.0736720.228 %
64×640.0736280.0736720.059 %

3D CFD — lid-driven cavity Re=100

Reference: Ghia et al. 1982: u_min = −0,2109 · v_min = −0,2453
Resolutionu_minv_minu_min deviation
16³-0.193-0.2148.41 %
32³ (test suite)−0,209−0,2390,8 %

Seismic — modal analysis (shear frame)

Reference: ω₁ = 2·√(k/m)·sin(π/(2(2n+1)))
Structuref₁ (Hz)referencedeviation
1 storey(s)1.12541.12540.0000 %
2 storey(s)0.69550.69550.0000 %
3 storey(s)0.50080.50080.0000 %
4 storey(s)0.39080.39080.0000 %

Seismic — response spectrum

Reference: resonance at T = 1/f₀ = 1,0 s
peak at T (s)referencedeviationamplification
1.01,00.0 %S_a max 3.59 > PGA 1.29

3D FEM — torsion of a solid shaft (meshed cylinder)

Reference: τ_max = 16·T/(π·d³) = 47,16 MPa (Saint-Venant, d=30 mm, T=250 N·m)
Meshτ_max (MPa)referencedeviation
2×12×448.2947.162.41 %
3×16×647.7647.161.29 %
4×24×847.4747.160.67 %

3D FEM — bending of a cantilever beam

Reference: σ_max = 6·F·l/(b·h²) = 40 MPa (strength of materials, beam 500×50×30 mm, F=1 kN)
Meshσ_xx max (MPa)referencedeviation
16×8×432.3240.0019.20 %
24×12×439.3340.001.66 %

Structure — column buckling (beam elements)

Reference: P_cr = π²·E·I/(K·L)² (Euler, column 2000×40×40 mm)
MeshP_cr (N)Euler (N)deviation
4 el.110596.2110539.60.0512 %
8 el.110543.2110539.60.0033 %
20 el.110539.7110539.60.0001 %

Structure — natural modes of a beam (consistent mass)

Reference: f₁ = β²/(2πL²)·√(E·I/(ρ·A)) (β = π pinned-pinned, steel beam 1000×40×40 mm)
Meshf₁ (Hz)referencedeviation
4 el.93.83893.8130.0260 %
8 el.93.81593.8130.0016 %
20 el.93.81393.8130.0000 %

Dynamics — Newmark-β (1 DOF, undamped step)

Reference: u_peak = 2·F/k = 0,05 m
Loadu_pic (m)referencedeviation
step0.050000.050000.000 %

Electromagnetic — solenoid & conductors

Reference: B = μ₀·N·I/√(L²+4R²) · F = μ₀·I₁·I₂·L/(2π·d)
Casecomputedreferencedeviation
solenoid (centre)0.024645 T0.024645 Texact
solenoid (∞ limit)0.025133 T0.025133 Texact
parallel wires (force)0.001000 N0.001000 Nexact

Fatigue — Goodman criterion

Reference: n = 1/(σ_a/Se + σ_m/Sut) = 2,988 (σ_m = 0)
Casecomputed nreferencedeviation
σ_m = 0 (fully reversed)2.98782.9878exact

Thermal — 2D conduction (∇²T = 0, Jacobi)

Reference: linear T(x) → T_centre = 50 °C · q = k·ΔT/L = 140 W/m²
GridT_centre (°C)referencedeviation
20×2050.000050,00.00000 %
40×4050.000050,00.00000 %
60×6050.000050,00.00000 %

Acoustics — Sabine / level / mass law

Reference: T60 = 0,161·V/A · Lp = Lw − 20·log10(r) − 11 · TL = 20·log10(m·f) − 47
Casecomputedreferencedeviation
Sabine T600.805 s0,805 sexact
level Lp59.0 dB59,0 dBexact
mass law TL33.0 dB33,0 dBexact

Thermal — transient conduction (FTCS)

Reference: linear steady state T(x)
Gridmax deviationreferenceconvergence
60 points7.52e-12 °C0 °Cconverges

Thermal — 3D conduction (3D Jacobi)

Reference: linear T(x) → T_centre = 50 °C · q = k·ΔT/L
GridT_centre (°C)referencedeviation
20³50.000050,00.0000 %

Dynamics — multi-DOF Newmark (cantilever beam)

Reference: steady state δ = F·L³/(3·E·I) = 7,4405 mm
Meshu_tip (m)referencedeviation
10 el.0.007440.007440.007 %

Compressible flow — isentropic & nozzle

Reference: P₀/P = (T₀/T)^(γ/(γ−1)) = 7,824 · A/A* = 1,6875 (M=2)
Casecomputedreferencedeviation
isentropic M=27.8247,824exact
nozzle M=21.68751,6875exact

Heat exchanger — LMTD & ε-NTU

Reference: ΔT_lm = (ΔT₁−ΔT₂)/ln(ΔT₁/ΔT₂) · ε-NTU (counter-flow)
Casecomputedreferencedeviation
counter-flow LMTD64.87 K64,87 Kexact
ε-NTU (Cr=0,5, NTU=2)0.77460,7746exact

Heat transfer — convection & radiation

Reference: Q = h·A·ΔT = 500 W · Q = ε·σ·A·T⁴ = 413,4 W
Casecomputedreferencedeviation
convection (Newton)500 W500 Wexact
radiation (Stefan-Boltzmann)413.4 W413,4 Wexact

Harmonic response (transfer function)

Reference: static f=0 → |X| = F/k
Caseamplitudereferencedeviation
static f=00.025000.02500exact

Cooling fin (extended surface)

Reference: Q = √(hPkA_c)·θ_b·tanh(mL) = 37,84 W
CaseQ (W)referencedeviation
aluminium 100×10×100 mm37.84 W37,84 Wexact

Thin plate bending (Navier series)

Reference: w = 0,00406·q·a⁴/D (Timoshenko)
Seriesw_centre (mm)referencedeviation
80 terms0.0264 mm0.0264 mm0.058 %

Optics — Snell's law

Reference: n₁·sin θ₁ = n₂·sin θ₂ → 19,47°
Caserefracted anglereferencedeviation
Snell 30° → glass19.47°19,47°exact

Solveurs analytiques — formules fermées exactes

Ces 21 solveurs sont des FORMULES FERMÉES : le résultat est exact par construction (écart 0 %), pas une approximation convergente.
SolveurFormule exactedeviation
Réservoir sous pression (mince / Lamé)σ_θ = p·r/t ; σ_l = p·r/(2t)0 %
Transmission (engrenage / roulement)i = Z₂/Z₁ ; L₁₀ = (C/P)^p·10⁶0 %
Ressort hélicoïdalk = G·d⁴/(8·D³·n) ; τ_max = 8·F·D/(π·d³)·K_w0 %
Torsion de Saint-Venant (rectangulaire)J = b·t³/3 ; τ_max = 3·T/(b·t²)0 %
Contact de Hertz (ponctuel / linéique)p_max = 2·P/(π·b·L) ; a = (3PR/(4E*))^(1/3)0 %
Pertes de charge (Darcy-Weisbach)f = 64/Re (laminaire) ; ΔP = f·(L/D)·ρv²/20 %
Électrostatique (Coulomb / condensateurs)F = q₁q₂/(4πε₀r²) ; C = ε₀εrA/d0 %
Flambement de plaque minceσ_cr = k·π²·E/(12(1−ν²))·(t/b)², k = 4 (carrée)0 %
Fatigue — dommage cumulé de MinerD = Σ(n_i/N_i) ; vie = 1/D0 %
Effort tranchant à la base (sismique)V = C_s·W ; C_s = min(S_DS, S_D1/T)/(R/I_e)0 %
Poutre sur appui élastique (Winkler)w_max = P·β/(2k) ; M_max = P/(4β)0 %
Induction électromagnétique (Faraday)L = μ₀·N²·A/l ; e = −ΔΦ/Δt ; e = B·L·v0 %
Conduction avec génération volumiqueT_max = T_s + q'''·e²/(8k)0 %
Poutre en charge répartie uniformeδ = 5·w·L⁴/(384EI) ; M = w·L²/80 %
Résistance thermique multicoucheR = Σ L_i/(k_i·A) ; Q = ΔT/R0 %
Diffusion de matière (loi de Fick)J = −D·ΔC/L ; τ = L²/D0 %
Résonateur de Helmholtzf = (c/2π)·√(A/(V·L_eff))0 %
Réseau de diffractiond·sin θ = m·λ ; R = m·N0 %
Aérodynamique (traînée / portance)F_d = ½·ρ·v²·C_d·A ; F_l = ½·ρ·v²·C_l·A0 %
Bernoulli (Torricelli / Venturi)v = √(2·g·h) ; v₂ = √(2·ΔP/(ρ·(1−(A₂/A₁)²)))0 %
Assemblage vissé (boulon)T = K·F·d ; σ = F/(π·d²/4) ; p = F/(π/4·(D_o²−d²))0 %
Decision-support analysis — NOT a certification (2.711, §§): human validation and systematic procedures required.